This Is How Full Spectrum Cytometry Works

The process of fluorescence starts with a photon of light, which causes the excitation of a compound that releases the absorbed energy by emitting a photon of light. This process is very rapid (typically occurring in nanoseconds), and the emitted photon is of higher wavelength (thus lower energy) than the exciting photon. Here is your guide to how full spectrum cytometry works.

Tools, such as spectral viewers, allow researchers to visualize the spectral profiles of different fluorochromes. Take the fluorescence emission of AlexaFluorⓇ488, which is displayed using the Biolegend spectral viewer.

Figure 1:  Emission profile of AlexaFluorⓇ488. The blue line is the 488 nm excitation line.  

As can be seen, the maximal excitation of this molecule is ~517 nm, but the possible range of emitted photons can reach to over 600 nm.  

In the design of most traditional fluorescence flow cytometry, each detector has a specific filter in front of it that controls the specific wavelength of captured photons. The blue line represents a 520/20 bandpass filter that allows light between 510-530 nm to be measured.  

What if, instead of capturing only 20 nm of light from the emission of this molecule, it was possible to capture the entire spectrum of the emitted fluorescence? If this were possible, more information about each molecule could be captured, allowing for new combinations of fluorochromes that are not traditionally used together. It also would allow us to use more fluorochromes per experiment. 

‘Spectral cytometry’ or better named, Full Spectrum Cytometry, takes advantage of this idea, and has been commercialized by three companies – Sony, Cytek, and Propel, the most recent entry into this field. A quick search on PubMed shows that the first articles on this topic appeared in 1980 and have been on a growth trajectory since then, as shown below. 

Figure 2:  Growth of articles in PubMed with the terms ‘Spectral Flow Cytometry’ or ‘Full Spectrum Cytometry.’

Take a look at the Sony system, which uses a prism-based separation of the incoming light, sending it to a 32 channel PMT.

Figure 3:  The SONY full spectrum cytometry technology. From the Sony webpage.  

The Cytek system, the Aurora, uses multiple Avalanche Photodiodes (APD)s with specific filters in front of each, to capture the fluorescence data. The optical layout of this system is shown below, taken from the Aurora users guide.

Figure 4:  The Aurora optical layout. 

An example of the number of channels and wavelengths that are measured can be seen in this chart for the blue detector module which has 14 detectors.

Figure 5: Filter configuration for the Blue Detection Module.

One advantage of full spectrum cytometry is capturing the autofluorescence (AF) of cells and using that as a separate spectrum that can be used to remove the AF, allowing for better resolution of the actual signal. As shown in this data from the Sony website where liposomes from cells that expressed GFP were analyzed. In the panel on the left, there appears to be a range of GFP+ expression, including some events along a diagonal. By removing the AF signal, the data is cleaned up and an accurate count of GFP+ liposomes is determined.

Figure 6:  The removal of AF helps to improve the ability to detect fluorescent signals. 

Full-spectrum cytometry also allows for closely related dyes, that would not work together in traditional fluorescent cytometry, to be used in panels on these spectral cytometers.  Take, for example, AlexaFluorⓇ 647 and APC, as shown in this spectral plot and a traditional 660/20 BP filter. It is not possible to use these with a single filter.

Figure 7:  APC (purple) and AlexaFluorⓇ 700 (blue) emission spectra. 

Now, if we look at the same two probes under full-spectrum, in this case, using a 4-laser Aurora, it is clear that these two dyes are different enough and can be separated. 

Figure 8:  APC (purple) and AlexaFluorⓇ 700 (blue) emission spectra. 

As shown from this data from Cytek, cells were gated on CD3+ cells, and CD8 (APC) vs. CD56 (AF6447) are plotted (Test), showing clear separation. For comparison, the control plot shows CD3+ cells were gated, and CD8 (APC) vs. CD56 (PE) is shown, and the results are comparable.

Figure 9:  Results of spectral deconvolution of two overlapping dyes. Data from Cytek.

Full Spectrum Cytometry offers a new mode to measure fluorescence and offers lots of opportunities to expand panels and improve detection, especially in highly autofluorescent cells. Of course, with great power comes great responsibility, and no instrument, no technique can rescue poorly designed experiments. Join us next time for part two of Spectral Cytometry, where we will discuss experimental design. 

To learn more about other important methods for your flow cytometry lab, and to get access to all of our advanced materials including 20 training videos, presentations, workbooks, and private group membership, get on the Flow Cytometry Mastery Class wait list.

Written By: Tim Bushnell, Ph.D.

The process of fluorescence starts with a photon of light, which causes the excitation of a compound that releases the absorbed energy by emitting a photon of light. This process is very rapid (typically occurring in nanoseconds), and the emitted photon is of higher wavelength (thus lower energy) than the exciting photon. Tools, such as spectral viewers, allow researchers to visualize the spectral profiles of different fluorochromes. Take the fluorescence emission of AlexaFluorⓇ488, which is displayed using the Biolegend spectral viewer.

Figure 1:  Emission profile of AlexaFluorⓇ488. The blue line is the 488 nm excitation line.  

As can be seen, the maximal excitation of this molecule is ~517 nm, but the possible range of emitted photons can reach to over 600 nm.  

In the design of most traditional fluorescence flow cytometry, each detector has a specific filter in front of it that controls the specific wavelength of captured photons. The blue line represents a 520/20 bandpass filter that allows light between 510-530 nm to be measured.  

What if, instead of capturing only 20 nm of light from the emission of this molecule, it was possible to capture the entire spectrum of the emitted fluorescence? If this were possible, more information about each molecule could be captured, allowing for new combinations of fluorochromes that are not traditionally used together. It also would allow us to use more fluorochromes per experiment. 

‘Spectral cytometry’ or better named, Full Spectrum Cytometry, takes advantage of this idea, and has been commercialized by three companies – Sony, Cytek, and Propel, the most recent entry into this field. A quick search on PubMed shows that the first articles on this topic appeared in 1980 and have been on a growth trajectory since then, as shown below. 

Figure 2:  Growth of articles in PubMed with the terms ‘Spectral Flow Cytometry’ or ‘Full Spectrum Cytometry.’

Take a look at the Sony system, which uses a prism-based separation of the incoming light, sending it to a 32 channel PMT.

Figure 3:  The SONY full spectrum cytometry technology. From the Sony webpage.  

The Cytek system, the Aurora, uses multiple Avalanche Photodiodes (APD)s with specific filters in front of each, to capture the fluorescence data. The optical layout of this system is shown below, taken from the Aurora users guide.

Figure 4:  The Aurora optical layout. 

An example of the number of channels and wavelengths that are measured can be seen in this chart for the blue detector module which has 14 detectors.

Figure 5: Filter configuration for the Blue Detection Module.

One advantage of full spectrum cytometry is capturing the autofluorescence (AF) of cells and using that as a separate spectrum that can be used to remove the AF, allowing for better resolution of the actual signal. As shown in this data from the Sony website where liposomes from cells that expressed GFP were analyzed. In the panel on the left, there appears to be a range of GFP+ expression, including some events along a diagonal. By removing the AF signal, the data is cleaned up and an accurate count of GFP+ liposomes is determined.

Figure 6:  The removal of AF helps to improve the ability to detect fluorescent signals. 

Full-spectrum cytometry also allows for closely related dyes, that would not work together in traditional fluorescent cytometry, to be used in panels on these spectral cytometers.  Take, for example, AlexaFluorⓇ 647 and APC, as shown in this spectral plot and a traditional 660/20 BP filter. It is not possible to use these with a single filter.

Figure 7:  APC (purple) and AlexaFluorⓇ 700 (blue) emission spectra. 

Now, if we look at the same two probes under full-spectrum, in this case, using a 4-laser Aurora, it is clear that these two dyes are different enough and can be separated. 

Figure 8:  APC (purple) and AlexaFluorⓇ 700 (blue) emission spectra. 

As shown from this data from Cytek, cells were gated on CD3+ cells, and CD8 (APC) vs. CD56 (AF6447) are plotted (Test), showing clear separation. For comparison, the control plot shows CD3+ cells were gated, and CD8 (APC) vs. CD56 (PE) is shown, and the results are comparable.

Figure 9:  Results of spectral deconvolution of two overlapping dyes. Data from Cytek.

Full Spectrum Cytometry offers a new mode to measure fluorescence and offers lots of opportunities to expand panels and improve detection, especially in highly autofluorescent cells. Of course, with great power comes great responsibility, and no instrument, no technique can rescue poorly designed experiments. Join us next time for part two of Spectral Cytometry, where we will discuss experimental design. 

To learn more about other important methods for your flow cytometry lab, and to get access to all of our advanced materials including 20 training videos, presentations, workbooks, and private group membership, get on the Flow Cytometry Mastery Class wait list.

Join Expert Cytometry's Mastery Class

ABOUT TIM BUSHNELL, PHD

Tim Bushnell holds a PhD in Biology from the Rensselaer Polytechnic Institute. He is a co-founder of—and didactic mind behind—ExCyte, the world’s leading flow cytometry training company, which organization boasts a veritable library of in-the-lab resources on sequencing, microscopy, and related topics in the life sciences.

Tim Bushnell, PhD

Similar Articles

The Power Of Spectral Viewers And Their Use In Full Spectrum Flow Cytometry

The Power Of Spectral Viewers And Their Use In Full Spectrum Flow Cytometry

By: Tim Bushnell, PhD

What photon from yonder fluorochrome breaks?  It is … umm… hmmm. Let me see. Excitation off a 561 nm laser, with an emission maximum of 692 nm. I’m sure if Shakespeare was a flow cytometrist, he might have written that very scene. But the play is lost in time. However, since the protagonist had difficulty determining what fluorochrome was emitting photons, let’s consider how this could be figured out. In my opinion, one of the handiest flow cytometry tools is the spectral viewer. This tool helps visualize the excitation and emission profile of different fluorochromes, as well as allowing you…

Fickle Markers: Solutions For Antibody Binding Specificity Challenges

Fickle Markers: Solutions For Antibody Binding Specificity Challenges

By: Tim Bushnell, PhD

Reproducibility has been an ongoing, and important, concept in the sciences for years.  In the area of biomedical research, the alarm was sounded by several papers published in the early 2010’s.  Authors like Begley and Ellis, Prinz and coworkers, and Vasilevsky and colleagues, among others reported an alarming trend in the reproducibility of pre-clinical data.  These reports indicated between 50% to almost 90% of published pre-clinical data were not reproducible.  This was further highlighted in the article by Freedman and coworkers, who tried to identify and quantify the different sources of error that could be causing this crisis.  Figure 1,…

5 Common Flow Cytometry Questions, Answered

5 Common Flow Cytometry Questions, Answered

By: Tim Bushnell, PhD

I want to thank all of you who send us your questions about flow cytometry, so I thought I would dip into the old email bag and answer a few of the common ones here.  If your question isn’t answered this time, look for it to be answered in a future blog post.  Of course, if you want us to cover a specific topic, drop us a line.  1. How Fast Can I Go? This is  a common question. The allure of the ‘hi’ button is hard to resist.  The faster you go, the sooner you are finished with data…

Combining Flow Cytometry With Plant Science, Microorganisms, And The Environment

Combining Flow Cytometry With Plant Science, Microorganisms, And The Environment

By: Tim Bushnell, PhD

My first introduction to flow cytometry was talking to a professor who’d brought one on a research cruise to study phytoplankton. It was only later that I was introduced to the marvelous world that’s been my career for over 20 years.   In that time, I’ve had the opportunity to work with researchers in many different areas, exposing me to a wide variety of cell types and more important assays. What continues to amaze me is the number of different parameters we can measure, not just the number of fluorochromes, but the information we can extract from samples – animal, vegetable…

Common Numbers-Based Questions I Get As A Flow Cytometry Core Manager And How To Answer Them

Common Numbers-Based Questions I Get As A Flow Cytometry Core Manager And How To Answer Them

By: Tim Bushnell, PhD

Numbers are all around us.  My personal favorite is ≅1.618 aka ɸ aka ‘the golden ratio’.  It’s found throughout history, where it has influenced architects and artists. We see it in nature, in plants, and it is used in movies to frame shots. It can be approximated by the Fibonacci sequence (another math favorite of mine). However, I have not worked out how to apply this to flow cytometry.  That doesn’t mean numbers aren’t important in flow cytometry. They are central to everything we do, and in this blog, I’m going to flit around numbers-based questions that I have received…

3 Must-Have High-Dimensional Flow Cytometry Controls

3 Must-Have High-Dimensional Flow Cytometry Controls

By: Tim Bushnell, PhD

Developments such as the recent upgrade to the Cytobank analysis platform and the creation of new packages such as Immunocluster are reducing the computational expertise needed to work with high-dimensional flow cytometry datasets. Whether you are a researcher in academia, industry, or government, you may want to take advantage of the reduced barrier to entry to apply high-dimensional flow cytometry in your work. However, you’ll need the right experimental design to access the new transformative insights available through these approaches and avoid wasting the considerable time and money required for performing them. As with all experiments, a good design begins…

The Fluorochrome Less Excited: How To Build A Flow Cytometry Antibody Panel

The Fluorochrome Less Excited: How To Build A Flow Cytometry Antibody Panel

By: Tim Bushnell, PhD

Fluorochrome, antibodies and detectors are important. The journey of a thousand cells starts with a good fluorescent panel. The polychromatic panel is the combination of antibodies and fluorochromes. These will be used during the experiment to answer the biological question of interest. When you only need a few targets, the creation of the panel is relatively straightforward. It’s only when you start to get into more complex panels with multiple fluorochromes that overlap in excitation and emission gets more interesting.  FLUOROCHROMES Both full spectrum and traditional fluorescent flow cytometry rely on measuring the emission of the fluorochromes that are attached…

Flow Cytometry Year in Review: Key Changes To Know

Flow Cytometry Year in Review: Key Changes To Know

By: Meerambika Mishra

Here we are, at the end of an eventful year 2021. But with the promise of a new year 2022 to come. It has been a long year, filled with ups and downs. It is always good to reflect on the past year as we move to the future.  In Memoriam Sir Isaac Newton wrote “If I have seen further, it is by standing upon the shoulders of giants.” In the past year, we have lost some giants of our field including Zbigniew Darzynkiwicz, who contributed much in the areas of cell cycle analysis and apoptosis. Howard Shapiro, known for…

What Star Trek Taught Me About Flow Cytometry

What Star Trek Taught Me About Flow Cytometry

By: Tim Bushnell, PhD

It is no secret that I am a very big fan of the Star Trek franchise. There are many good episodes and lessons explored in the 813+ episodes, 12 movies (and counting). Don’t worry, this blog is not going to review all 813, or even 5 of them. Instead, some of the lessons I have taken away from the show that have applicability to science and flow cytometry.  “Darmok and Jalad at Tanagra.”  (ST:TNG season 5, episode 2) This is probably one of my favorite episodes, which involves Picard and an alien trying to establish a common ground and learn…

Top Industry Career eBooks

Get the Advanced Microscopy eBook

Get the Advanced Microscopy eBook

Heather Brown-Harding, PhD

Learn the best practices and advanced techniques across the diverse fields of microscopy, including instrumentation, experimental setup, image analysis, figure preparation, and more.

Get The Free Modern Flow Cytometry eBook

Get The Free Modern Flow Cytometry eBook

Tim Bushnell, PhD

Learn the best practices of flow cytometry experimentation, data analysis, figure preparation, antibody panel design, instrumentation and more.

Get The Free 4-10 Compensation eBook

Get The Free 4-10 Compensation eBook

Tim Bushnell, PhD

Advanced 4-10 Color Compensation, Learn strategies for designing advanced antibody compensation panels and how to use your compensation matrix to analyze your experimental data.