3 Advantages Of Using The ZE5 Cell Analyzer

Since the first laser was mounted to create the first flow cytometer, there has been a push for more – more lasers, more detectors, and more colors.

Why?

So researchers could ask more complicated questions to squeeze every iota of data out of rare events and precious samples, and so clinicians could expand the diagnostics capabilities of the technology. In addition, this trend has occurred so biotech companies could expand high-content screening for drug discovery.

Instrument manufacturers have brought to the table a plethora of different instruments, with capabilities to suit the needs of the researcher, at price points to make the accountants happy, with all improvements in hardware, software and automation to make the operator’s job easier. Often, these are based on an extension of the available equipment a vendor currently has.

Due to these improvements, the average researcher today has capabilities that were previously possible in only a very few specialized laboratories.

The Democratization of Flow Cytometry

What happens when an instrument manufacturer takes a step back, evaluates needs of different constituencies, and embarks on a journey to build a machine from the ground up, taking the best in technology and workflow to bring something novel to market that enables more users to gain access to the highest level capabilities?

A democratization of flow cytometry, and perhaps science in general.

As a core manager, some of the characteristics that are important in evaluating a potential new instrument include sensitivity, flexibility, and capacity. When thinking about training users, an easy to user interface is a must. If the software interface is too complicated, the system will sit in the corner and collect dust. Automation of common tasks from startup, to instrument cleaning, to quality control, are bonuses.

Researchers need to have a large number of lasers and detectors to ensure current panels can be run and new, expanded panels can be developed. Fast, automated acquisition is important to allow more to get done during the day. And, an easy to use software to reduce the barrier to access is a must.

This is a tall order because, in general, making one decision to improve a cell analyzer can limit the analyzer in other ways.

For example, fast acquisition with multiple lasers requires fast electronics and responsive optics, which can drive the cost of the instrument higher. Likewise, automation of common tasks can require complex software and monitoring devices, which may both increase price and decrease ease of access.

It may seem like an impossible task, but the team of Bio-Rad and Propel Laboratories, collaborated to bring the ZE5™ Cell Analyzer to the market and, with thoughtful design, the Analyzer answers these challenges, resulting in a high-end, easy to use, automated flow cytometer.

3 Advantages Of Using The ZE5 Flow Cytometer

Starting with the standard flow cytometry workflow, the ZE5 is the cytometrist’s cytometer.

On-board and automated quality control systems ensure the instrument starts up at the beginning of the day, and shuts down at the end of the day. More than that, the system has a novel development called the ‘ZE5-EYE’.

This system monitors all the laser spots, making sure the correct filter is in place and, more importantly, continues to monitor the system performance during the day, notifying users if there is a problem BEFORE they run their samples.

Overall, the ZE5 offers 3 unique advantages to cytometrists and end-users alike…

1. User Friendly Software With A Panel Design Tool

The ZE5’s advanced software system is called Everest™. But, don’t be fooled by its advanced capabilities.

Everest is easy to use and intuitive, which means even the most novice of users will not be intimidated as they learn to perform their flow cytometry experiments.

In addition, the software aids in the panel design process, and allows the researcher to view, on the instrument, the best fluorochrome/laser/filter combinations, which is essential for the development of a high-end polychromatic panel.

2. High-End Construction And Advanced Capabilities

With 5 lasers, the ZE5 has the range to take advantage of all commercially available dyes.

Another positive feature is the lasers are liquid-cooled. This helps maintain laser stability, especially on hot (and humid) days in the lab.

The fluidics have been re-thought too. For those familiar with the swappable fluidics of the S3e™ Cell Sorter also from Bio-Rad, it will come as no surprise that the ZE5 has a similar fluidics system. So, if a researcher has a long run, they don’t have to depressurize the system to refill the sheath tanks.

Instead, with the ZE5, you can hot-swap the fluidics with no loss of sample integrity during long acquisitions.

3. Lightening Fast Acquisition Speed Without Sacrificing Quality

Acquisition speed always has been a limitation on many systems. Slow systems increase the time to collect sufficient events to do rare event (and really rare event) analysis, and make rare event analysis tedious and time-consuming.

This is not the case with the ZE5, as seen in the figure below…

Figure 1: This graph shows the acquisition speed capabilities of the ZE5. Bangs Labs, Dragon Green Beads were used in a serial dilution to determine when cell count falls off the theoretical limit. The ZE5 outperforms other systems at higher acquisition speeds as it continues to acquire data into the 100,000 event per second range, whereas the competitive systems fall off around 20,000 events per second. Data and graph courtesy of Karen Helm, MT(ASCP) from the University of Colorado Cancer Center.

The ZE5 tops out at a level up to 100,000 events per second, making those 10-minute run times a thing of the past, in many cases. Even more impressive is the fact that the data spread and loss of events due to hard aborts and coincident events is tolerable at that high rate.

As mentioned, today’s researchers require a large number of lasers and detectors to ensure current panels can be run and expanded panels can be developed. The problem is that improving a cell analyzer in one direction can limit the analyzer in another direction. The ZE5 Cell Analyzer solves this problem with their new flow cytometer that includes user-friendly Everest software, high-end construction and capabilities, and blazing fast, high-quality acquisition speed.

To learn more about the ZE5 Cell Analyzer from Bio-Rad, and how to analyze your cells properly and faster acquisition speeds, click here.

Join Expert Cytometry's Mastery Class

ABOUT TIM BUSHNELL, PHD

Tim Bushnell holds a PhD in Biology from the Rensselaer Polytechnic Institute. He is a co-founder of—and didactic mind behind—ExCyte, the world’s leading flow cytometry training company, which organization boasts a veritable library of in-the-lab resources on sequencing, microscopy, and related topics in the life sciences.

Tim Bushnell, PhD

Similar Articles

The Power Of Spectral Viewers And Their Use In Full Spectrum Flow Cytometry

The Power Of Spectral Viewers And Their Use In Full Spectrum Flow Cytometry

By: Tim Bushnell, PhD

What photon from yonder fluorochrome breaks?  It is … umm… hmmm. Let me see. Excitation off a 561 nm laser, with an emission maximum of 692 nm. I’m sure if Shakespeare was a flow cytometrist, he might have written that very scene. But the play is lost in time. However, since the protagonist had difficulty determining what fluorochrome was emitting photons, let’s consider how this could be figured out. In my opinion, one of the handiest flow cytometry tools is the spectral viewer. This tool helps visualize the excitation and emission profile of different fluorochromes, as well as allowing you…

3 Must-Have High-Dimensional Flow Cytometry Controls

3 Must-Have High-Dimensional Flow Cytometry Controls

By: Tim Bushnell, PhD

Developments such as the recent upgrade to the Cytobank analysis platform and the creation of new packages such as Immunocluster are reducing the computational expertise needed to work with high-dimensional flow cytometry datasets. Whether you are a researcher in academia, industry, or government, you may want to take advantage of the reduced barrier to entry to apply high-dimensional flow cytometry in your work. However, you’ll need the right experimental design to access the new transformative insights available through these approaches and avoid wasting the considerable time and money required for performing them. As with all experiments, a good design begins…

The Fluorochrome Less Excited: How To Build A Flow Cytometry Antibody Panel

The Fluorochrome Less Excited: How To Build A Flow Cytometry Antibody Panel

By: Tim Bushnell, PhD

Fluorochrome, antibodies and detectors are important. The journey of a thousand cells starts with a good fluorescent panel. The polychromatic panel is the combination of antibodies and fluorochromes. These will be used during the experiment to answer the biological question of interest. When you only need a few targets, the creation of the panel is relatively straightforward. It’s only when you start to get into more complex panels with multiple fluorochromes that overlap in excitation and emission gets more interesting.  FLUOROCHROMES Both full spectrum and traditional fluorescent flow cytometry rely on measuring the emission of the fluorochromes that are attached…

Flow Cytometry Year in Review: Key Changes To Know

Flow Cytometry Year in Review: Key Changes To Know

By: Meerambika Mishra

Here we are, at the end of an eventful year 2021. But with the promise of a new year 2022 to come. It has been a long year, filled with ups and downs. It is always good to reflect on the past year as we move to the future.  In Memoriam Sir Isaac Newton wrote “If I have seen further, it is by standing upon the shoulders of giants.” In the past year, we have lost some giants of our field including Zbigniew Darzynkiwicz, who contributed much in the areas of cell cycle analysis and apoptosis. Howard Shapiro, known for…

What Star Trek Taught Me About Flow Cytometry

What Star Trek Taught Me About Flow Cytometry

By: Tim Bushnell, PhD

It is no secret that I am a very big fan of the Star Trek franchise. There are many good episodes and lessons explored in the 813+ episodes, 12 movies (and counting). Don’t worry, this blog is not going to review all 813, or even 5 of them. Instead, some of the lessons I have taken away from the show that have applicability to science and flow cytometry.  “Darmok and Jalad at Tanagra.”  (ST:TNG season 5, episode 2) This is probably one of my favorite episodes, which involves Picard and an alien trying to establish a common ground and learn…

5 Flow Cytometry Strategies That Sun Tzu Taught Me

5 Flow Cytometry Strategies That Sun Tzu Taught Me

By: Tim Bushnell, PhD

Sun Tzu was a Chinese general and philosopher. His most famous writing is ‘The Art of War’, and has been studied by generals and CEOs, to glean ideas and strategies to help their missions. I was recently rereading this work and thought to myself if any of Sun Tzu’s lessons could apply to flow cytometry.  So I have identified 5 points that I think lend themselves to thinking about flow cytometry.  “Quickness is the essence of the war.” In flow cytometry, speed is of the essence. The longer the cells are out of their natural environment, the less happy they…

A Basic Guide To Flow Cytometry (3 Foundational Concepts)

A Basic Guide To Flow Cytometry (3 Foundational Concepts)

By: Meerambika Mishra

Mastering foundational concepts are imperative for successfully using any technique or system.  Robert Heinlein introduced the term ‘Grok’  in his novel Stranger in a Strange Land. Ever since then it has made its way into popular culture. To Grok something is to understand it intuitively, fully. As a cytometrist, there are several key concepts that you must grok to be successful in your career. These foundational concepts are the key tools that we use day in and day out to identify and characterize our cells of interest.  Cells Flow cytometry measures biological processes at the whole cell level. To do…

Which Fluorophores To Use For Your Microscopy Experiment

Which Fluorophores To Use For Your Microscopy Experiment

By: Heather Brown-Harding, PhD

Fluorophore selection is important. I have often been asked by my facility users which fluorophore is best suited for their experiments. The answer to this is mostly dependent on whether they are using a widefield microscope with set excitation/emission cubes or a laser based system that lets you select the laser and the emission window. Once you have narrowed down which fluorophores you can excite and collect the correct emission, you can further refine the specific fluorophore that is best for your experiment.  In this blog  we will discuss how to determine what can work with your microscope, and how…

4 No Cost Ways To Improve Your Microscopy Image Quality

4 No Cost Ways To Improve Your Microscopy Image Quality

By: Heather Brown-Harding, PhD

Image quality is critical for accurate and reproducible data. Many people get stuck on the magnification of the objective or on using a confocal instead of a widefield microscope. There are several other factors that affect the image quality such as the numerical aperture of the objective, the signal-to-noise ratio of the system, or the brightness of the sample.  Numerical aperture is the ability of an objective to collect light from a sample, but it contributes to two key formulas that will affect your image quality. The first is the theoretical resolution of the objective. It is expressed with the…

Top Industry Career eBooks

Get the Advanced Microscopy eBook

Get the Advanced Microscopy eBook

Heather Brown-Harding, PhD

Learn the best practices and advanced techniques across the diverse fields of microscopy, including instrumentation, experimental setup, image analysis, figure preparation, and more.

Get The Free Modern Flow Cytometry eBook

Get The Free Modern Flow Cytometry eBook

Tim Bushnell, PhD

Learn the best practices of flow cytometry experimentation, data analysis, figure preparation, antibody panel design, instrumentation and more.

Get The Free 4-10 Compensation eBook

Get The Free 4-10 Compensation eBook

Tim Bushnell, PhD

Advanced 4-10 Color Compensation, Learn strategies for designing advanced antibody compensation panels and how to use your compensation matrix to analyze your experimental data.