5 Important Tips For Analyzing Your Data
![](https://cdn.expertcytometry.com/e/uploads/2014/01/Five-Important-Tips-For-Analyzing-Your-Data.jpg)
Depending on the experimental design, many researchers will be doing complex assays that will require statistical analysis to determine if the hypothesis being tested is statistically significant or not. Unfortunately, many researchers go about this analysis the wrong way, resulting in spurious conclusions. The following points are guides to help think about the steps necessary in flow cytometry data analysis.
1. Before you start
Define your hypothesis. This may sound simplistic, but understanding the purpose of the experiments is the first step in performing good statistical analysis. Stating the hypothesis will allow the researcher to choose the correct statistical test BEFORE the experiments are begun, and more importantly define the null hypothesis. The null hypothesis is what is assumes to be true until evidence shows it otherwise.
For example, if the experimental question is “does treatment of patients with drug X increases the number of mature B cells in circulation”, then the null hypothesis would be that “treatment of patients with drug X causes no change to the number of mature B cells in circulation.” With the null hypothesis in place, the type of test to be performed is obvious. In this case, a T-Test would be the logical choice for testing the null hypothesis.
2. Set your threshold.
The threshold value is an estimate of the probably that the result has occurred by a statistical accident – that is at random. It is accepted in science to set this at 0.05, which is interpreted as a 5% chance that the significant results occurred by an accident. There is no magic to 0.05, more of an accepted convenience first proposed by R.A. Fisher. Many scientists are moving to use a threshold of 0.01 or even 0.001 indicating a smaller change of significance being a result of an accident.
3. Know the numbers.
All populations can be described by two numbers, the central tendency and the spread of the data. Depending on the type of data being looked at, different measures should be used. In the case of expression data, the fluorescent intensity is best represented by the median value. It represents the midpoint of the data and is robust because one does not need to know the complete dataset, it does not assume a normal distribution and is resistant to outliers. In the case of the question above, the change in the percentage of a sub-population of cells, the mean value is a better choice, assuming the data follows a normal distribution.
Measuring distribution or spread of the data is done using the standard deviation. The smaller the SD, the tighter the data is clustered around the mean. In the case of the median, the robust SD (rSD) is one of several measures used to describe the deviation around the median. Another measure of deviation around the median is the MAD – median absolute deviation. The MAD is the median of the absolute value of the deviations from the median.
Confused? Don’t worry how the statistic is calculate, the software can do that for you. It is easy to remember Mean/SD and Median/rSD as a simple way to know what values should be used together.
4. Can’t forget controls.
Controls in flow are essential at many levels. These include the FMO control (for gating) to the unstimulated control (for setting background in stimulation experiments), to the reference control (used to ensure the experiment is reproducible and identify the biological variation in the experiment). Additionally, make sure that the correct control is being used for statistical analysis. The FMO control, for example, is not a control to use to identify the negatives in a statistical analysis. That role should be played by fully gated known negatives or background (unstimulated) cells.
5. Make sure you perform enough replicates.
This youtube video has made the rounds (http://www.youtube.com/watch?v=PbODigCZqL8) and is something that one needs to be careful of. Don’t use just 3 patients! To ensure enough replicates are performed, consider performing an a priori power analysis. In this analysis, an estimate of the differences between the Treatment and Control are made and the sample size needed to detect that difference is determined. The power of a statistical test is important in reducing Type II errors (the false negative). To improve statistical power in a test, consider adding more samples. The larger the sample size, the more power the statistical test will have.
Statistical analysis is a powerful tool in flow cytometry and should be considered as part of the initial experimental design, rather than at the end with the data are completely collected. Identifying the proper null hypothesis will lead to identifying the correct statistical test. Setting the proper threshold, rather than running the test and seeing what the returned P-value is an essential way to ensure the significance of the data is properly measured and understood. Finally, collect enough events and enough patient samples to ensure adequate power and minimize the change of a false negative error.
![Join Expert Cytometry's Mastery Class Join Expert Cytometry's Mastery Class](https://expertcytometry.com/wp-content/themes/cheeky-scientist-expert/assets/images/excyte-banner.jpg)
ABOUT TIM BUSHNELL, PHD
Tim Bushnell holds a PhD in Biology from the Rensselaer Polytechnic Institute. He is a co-founder of—and didactic mind behind—ExCyte, the world’s leading flow cytometry training company, which organization boasts a veritable library of in-the-lab resources on sequencing, microscopy, and related topics in the life sciences.
More Written by Tim Bushnell, PhD