How To Use A Threshold To Reduce Background Noise In Flow Cytometry

Pin It

Getting a clear signal with reduced noise is an essential component to good data. Adding a threshold when acquiring flow cytometry data is one way to do that. It reduces the number of events by setting a bar that a signal pulse must clear before it is counted as an event. Depending on the importance of the data, the downstream applications for the data (or sorted cells) will dictate how critical the threshold is. In combination with proper sample preparation, appropriate thresholding will reduce debris and ensure best outcome.

Read More

How Flow Cytometry Converts Photons To Digital Data

Flow Cytometry conversion of photons to electrons
Pin It

From photon, through conversion from light, into an electron, into an electronic signal pulse. The journey of a photon, through to its data representation via flow cytometry, involves the detection system and the electronics, and basically following a bouncing photon to its ultimate digitization. This article provides 3 key takeaways in the process from photons through to end data for analysis.

Read More

How To Use Flow Cytometry To Measure Apoptosis, Necrosis, and Autophagy

Flow Cytometry measuring apoptosis, necrosis, and autophagy
Pin It

Using flow cytometry and a host of different reagents, it is possible to tease out how your cells may have died. Using these tools, you can readily eliminate the various suspects and come to your conclusion as to how your treatment may have killed your cells of interest. Here are some reagents to consider when measuring apoptosis, necrosis, and autophagy.

Read More

How To Prepare For A Flow Cytometry Experiment

Preparation is vital before starting a flow cytometry experiment
Pin It

Flow cytometry is a very powerful tool and can answer many questions if the experiments are properly designed. There is a learning curve that takes a bit of time, patience, and practice, but soon you may be finding excuses to perform flow cytometry experiments and we will be here to help you with best practices. Using this checklist will help you to design and perform consistent experiments every time.

Read More

How To Differentiate T Cell State With Flow Cytometry

T Cell state differentation using flow cytometry
Pin It

T cell differentiation and effector function regulation is an area that needs to be better understood. Until then, speculation combined with best practices help you determine your T cell population’s status. Functional profiling is the primary determinant with surface markers as supporting evidence to assess whether your T cell is activated, resting, or naïve. Here are ways to help differentiate your T cells.

Read More